Common Problem
Your current position: Home > News > Common Problem
Equipment line (AWM) UL1015 specifications
Source: Xinya wire&cable Co.,LtdPopularity: 1280Time: 2017-02-21【SML】
UL1015
A. PVC insulated electronic wire
B. Conductor: 30AWG-2000kcmil (10AWG = 10kcmil)
C. Burning test: can be tested by horizontal
combustion
D. Rating: 80 ℃, 90 ℃, 105 ℃; 600V ac, 750V dc
E. Insulator: PVC, the thickness of the table
below
Specification
Average
minimum thickness
Minimum
thickness of any point
30AWG-9AWG
0.76mm
0.68mm
8AWG-7AWG
1.15mm
1.02mm
6AWG-2AWG
1.52mm
1.37mm
Prev: Equipment line (AWM) UL1061 specifications
Next: Equipment line (AWM) UL1185 specifications explanation
Related Information
Why does the wire need electronic irradiation
2017-03-15High frequency wire test debugging to explain
2017-03-13Equipment line (AWM) UL2919 specifications
2017-03-10Equipment line (AWM) UL2725 specifications explanation
2017-03-08Equipment line (AWM) UL2547 specifications
2017-03-07Equipment line (AWM) UL2517 specifications explanation
2017-03-06Equipment line (AWM) UL2468 specifications
2017-03-03Equipment line (AWM) UL2464 specifications explanation
2017-03-02Equipment line (AWM) UL2095 specifications explanation
2017-03-01Equipment cable (AWM) UL1792 specifications
2017-02-28Equipment line (AWM) UL1533 specifications explanation
2017-02-27Equipment line (AWM) UL1365 specifications explanation
2017-02-24